Étude expérimentale sur les évaporateurs à tubes ronds à ailettes et à micro-canaux pour un système de conditionnement d'air résidentiel.

Experimental study on microchannel and round tube plate fin evaporators in a residential air conditioning system.

Numéro : pap. 2472

Auteurs : LI H., HRNJAK P.

Résumé

The performance of two evaporators (round tube plate fin and microchannel) and their effect on system performances were experimentally investigated in R410A residential air conditioning systems. Both systems share identical components except evaporators and system performance were measured under AHRI A, B and C conditions. Under all test conditions, the system with the microchannel evaporator outperformed the baseline system with the round tube plate fin evaporator. Up to 10.6% increase of capacity and 13.1% increase of COP were achieved if both systems were operated under the same compressor speed. Up to 23.8% improvement of COP was obtained if the cooling capacities of both systems were kept the same. The refrigerant charge was reduced by 13.4% compared with the baseline system, due to the smaller internal volume of the microchannel evaporator. The air side heat transfer area of microchannel evaporator was just ½ of the baseline round tube plate fin evaporator, and so was the face area.

Documents disponibles

Format PDF

Pages : 9 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental study on microchannel and round tube plate fin evaporators in a residential air conditioning system.
  • Identifiant de la fiche : 30019017
  • Langues : Anglais
  • Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.