Etude expérimentale sur un nouveau transformateur de chaleur à absorption utilisant des mélanges actifs partiellement miscibles.

Experimental study of an innovative absorption heat transformer using partially miscible working mixtures.

Auteurs : ALONSO D., CACHOT T., HORNUT J. M.

Type d'article : Article

Résumé

This article describes the principle of an innovative heat transformer cycle using a working mixture that is partially miscible at low temperature. Hence, the separation step, classically done by distillation in an absorption heat pump, is replaced by a costless one in terms of energy, obtained by simply cooling down the mixture. Results of the operation of a laboratory scale pilot unit are presented. The machine operating on an n-heptane-DMF mixture has enabled an 8 °C temperature lift with thermal efficiency varying from 30 to 40%. Hence, the practical feasibility of such a cycle was demonstrated.

Détails

  • Titre original : Experimental study of an innovative absorption heat transformer using partially miscible working mixtures.
  • Identifiant de la fiche : 2004-0161
  • Langues : Anglais
  • Source : International Journal of thermal Sciences - vol. 42 - n. 6
  • Date d'édition : 06/2003

Liens


Voir d'autres articles du même numéro (1)
Voir la source