Evenly distributing the two-phase refrigerant over the paths significantly improves the evaporator’s efficiency. The fluid enters the evaporator in two phases, absorbing heat from the environment and vaporizing the liquid particles. It then exits the evaporator in a single phase, completing the refrigeration cycle by moving towards the suction line. In this study, R410A at 4 ◦C was considered the working fluid. Flow analysis was performed using a commercial CFD package according to inlet conditions of 0.1, 0.2 and 0.3 quality at flow rates of 50, 75 and 100 kg/h, with the outlet pressure fixed at 806 kPa. The effects of distributors positioned vertically and horizontally on maldistribution were examined, and it was determined that maldistribution was more prevalent in horizontal distributors at low flow rates. It was suggested that swirl generators could solve the problem of  aldistribution in the paths due to their centrifugal effect on the fluid. The flow then fully develops in the orifice and is distributed to the paths. The maldistribution values of the redesigned conical distributor and swirl generator distributors with swirl angles of 22.5◦, 30◦ and 45◦ under different operating conditions were then compared. The flow deviation value between the paths in the horizontal conical distributor was found to increase up to 83 %. This value decreases to 34.7 % at high flow rates. These deviation values are <10 % in swirl generator distributors. The designed swirl generator distributors are therefore a good alternative at low flow rates. 

Documents disponibles

Format PDF

Pages : 12 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A numerical study on fluid maldistribution in swirl generator distributors. 
  • Identifiant de la fiche : 30034303
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 178
  • Date d'édition : 10/2025
  • DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.07.004

Liens


Voir d'autres articles du même numéro (38)
Voir la source

Indexation

  • Thèmes : N/A
  • Mots-clés : N/A