Résumé
Computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC-11, HCFC-123, HCFC-141b under the same condition. The results showed that the COP of an optimized "non-split type" three-stage condensation heat pump was 25-42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the "non-split type" for the three-stage heat pump system.
Documents disponibles
Format PDF
Pages : 528-539
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A study on the performance of multistage condensation heat pumps.
- Identifiant de la fiche : 2001-0513
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 23 - n. 7
- Date d'édition : 11/2000
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
- Thèmes : Techniques des pompes à chaleur
- Mots-clés : Calcul; Pompe à chaleur; Performance; Système polyétage; Cycle thermodynamique
-
CYCLES D'ABSORPTION DE POMPES A CHALEUR D'UNE P...
- Auteurs : LAZZARIN R., LONGO G., ROSSETTO L.
- Date : 1988
- Langues : Italien
- Source : Termotecnica - vol. 42 - n. 10
Voir la fiche
-
Advanced absorption heat pump cycles.
- Auteurs : FURUTERA M., ORIGANE T., SAWADA T., KUNUGI Y., KASHIWAGI T., TAKEI T., AIZAWA M., MORI H.
- Date : 17/09/1996
- Langues : Anglais
- Source : Ab-sorption 96. Towards sustainable technologies. Proceedings./ Ab-sorption 96. Vers les technologies durables. Comptes rendus.
Voir la fiche
-
Multi-effect absorption chillers.
- Auteurs : ZIEGLER F., KAHN R., SUMMERER F., ALEFELD G.
- Date : 09/1993
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 16 - n. 5
- Formats : PDF
Voir la fiche
-
SIMULATION NUMERIQUE DES POMPES A CHALEUR A FON...
- Auteurs : KNOCHE K. F., STEHMEIER D.
- Date : 1984
- Langues : Allemand
- Source : Klima Kälte Heiz. - vol. 12 - n. 4
Voir la fiche
-
POMPES A CHALEUR A ABSORPTION, MULTIETAGEES. AN...
- Auteurs : LE GOFF P., LOUIS G., RAMADANE A.
- Date : 1988
- Langues : Français
- Source : Rev. gén. Therm. - vol. 27 - n. 320-321
Voir la fiche