Etude sur le facteur U d'une fenêtre avec un rideau en tissu.

A study of the U-factor of a window with a cloth curtain.

Auteurs : FANG X.

Type d'article : Article

Résumé

Heating and cooling energy calculations and building energy simulations need the overall heat-transfer coefficient (U-factor) of windows. The study focuses on the U-factor of a window with a cloth curtain indoors. Two side-by-side hot boxes are built in a laboratory for testing the window U-factors. The tested window systems are 100% glass area without frames which are equivalent to the center of glass of practical windows. The two types of tested window systems are the single glazing and the double glazing with a cloth curtain, respectively. The effect of curtain edge sealing conditions on U-factors is also studied.

Détails

  • Titre original : A study of the U-factor of a window with a cloth curtain.
  • Identifiant de la fiche : 2001-2816
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 21 - n. 5
  • Date d'édition : 04/2001

Liens


Voir d'autres articles du même numéro (3)
Voir la source