Etude sur les caractéristiques de fonctionnement d'un réfrigérateur domestique à cycle Stirling.

[In Japanese. / En japonais.]

Auteurs : OTAKA T., SAKAMOTO M., MURAKAMI K., et al.

Type d'article : Article

Résumé

The Stirling prototype using helium as working fluid is a kinematic drive, and beta type Stirling cycle machine of 100 W refrigerating capacity. The performance was evaluated as a function of cooling head temperature, mean pressure, frequency, and cooling capacity. The prototype has achieved the targeted refrigerating capacity of 100 W, and the COP of 1.02 under the design operational conditions, with 16.7 Hz frequency and 0.7 MPa helium pressure. The performance data were compared with the predicted ones.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 2001-2758
  • Langues : Japonais
  • Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 17 - n. 3
  • Date d'édition : 2000
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (20)
Voir la source