Evaluation d'un nouveau refroidisseur à cycle d'Ericsson noyé pour des applications de distributeurs automatiques.

Evaluation of a novel liquid-flooded Ericsson cycle cooler for vending machine applications.

Auteurs : HUGENROTH J., BRAUN J., GROLL E., et al.

Résumé

Research on a novel implementation of an Ericsson cycle heat pump for near ambient refrigeration applications was performed. The concept, termed a liquid-flooded Ericsson cooler, uses liquid flooding of the compressor and expander to approach isothermal compression and expansion processes. A numerical simulation of the cycle was developed and parametric studies were performed to explore the sensitivity of the cycle to changes in various system parameters such as, pressures, heat exchanger effectiveness and working fluids. The goal of the study was to assess the viability of the technology for vending machine applications. It was found that the target cooling coefficient of performance of 1.25 could be attained if the adiabatic efficiency of the compressor and expander were 85%.

Détails

  • Titre original : Evaluation of a novel liquid-flooded Ericsson cycle cooler for vending machine applications.
  • Identifiant de la fiche : 2010-0245
  • Langues : Anglais
  • Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
  • Date d'édition : 21/06/2009

Liens


Voir d'autres communications du même compte rendu (30)
Voir le compte rendu de la conférence