Évaluation de l'effet du lavage sur la capacité de transfert de chaleur et la résistance à l'écoulement côté air des condenseurs refroidis à l’air.

Evaluation the effect of washing on the heat transfer capacity and air-side flow resistance of air cooled condensers.

Numéro : pap. 2216

Auteurs : MEHRABI M., YUILL D.

Résumé

Air cooled condensers are commonly used in rooftop units and residential air-conditioners to reject heat outdoors. Airborne particles in the environment, such as dust, grass, leaves, seeds, and anthropogenic agents, can foul the air side of the condensers. Therefore, it is common practice to regularly clean the air side of condensers. Seven fouled wavy fin, and two fouled spine fin condensers from residential condensing units were collected at the end of their service lives, and examined in the laboratory to study the effect of the fouling on heat transfer capacity and air-side flow resistance. A test apparatus was designed and built to investigate the flow resistance and heat transfer of these coils before and after cleaning. After testing each condenser in the fouled condition, the fouling material was collected and its mass was measured. Then, the coil was washed with water and tested again in the test apparatus. Finally, to investigate the effectiveness of commercial detergents, these coils were cleaned with a detergent and tested again. Surprisingly, the results show that the effect of washing on the heat transfer capacity of the coil is very small, and in some cases, the fouled condenser performed better before cleaning than afterward. Similarly, cleaning the coils with detergent had negligible differences compared with the effects from cleaning with water only, and in some cases, the detergent caused performance degradation in terms of flow resistance and heat transfer.

Documents disponibles

Format PDF

Pages : 10

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Evaluation the effect of washing on the heat transfer capacity and air-side flow resistance of air cooled condensers.
  • Identifiant de la fiche : 30024452
  • Langues : Anglais
  • Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 09/07/2018

Liens


Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence