Document IIF
Évaluation de l'utilisation potentielle du R1132A comme composant d’un mélange de frigorigènes.
Evaluation of potential use of R1132A as a refrigerant blend component.
Numéro : pap. n. 1183
Auteurs : LOW R.
Résumé
Refrigeration applications requiring evaporation at temperatures in the range -50 to -100°C have traditionally used non-flammable fluids having very high GWP such as R-23 and R-508A/B. Some ultralow temperature appliances now use R-170 as an alternative, but its flammability can restrict its application to larger systems. The potential use of R-1132a (1,1-difluoroethene) as a blend component for new, lower GWP refrigerant mixtures to serve this application range is under current evaluation. This paper presents some initial results of thermodynamic property evaluation, performance testing and stability testing.
Documents disponibles
Format PDF
Pages : 8
Disponible
Gratuit
Détails
- Titre original : Evaluation of potential use of R1132A as a refrigerant blend component.
- Identifiant de la fiche : 30024876
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1183
Liens
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Evaluation of potential use of R1132A as a refr...
- Auteurs : LOW R.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
New high pressure low GWP refrigerant blends.
- Auteurs : COX N., MAZUR V., COLBOURNE D.
- Date : 2008
- Langues : Anglais
- Source : The Institute of Refrigeration: annual proceedings. Volume 105, 2008-2009.
Voir la fiche
-
Numerical study on the composition ratio change...
- Auteurs : YOON I., CHUNG H. J., KIM Y. C.
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche
-
Pushing the envelope: extending the range and p...
- Auteurs : LOW R.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Survey on non flammable low GWP refrigerant mix...
- Auteurs : GÖPFERT T., HESSE U.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche