Évaluation de la performance de distribution et optimisation de la structure d’un distributeur appliqué à un conditionneur d'air de faible diamètre.

[In Chinese. / En chinois.]

Auteurs : YANG G., WENG X., DING G., et al.

Type d'article : Article

Résumé

In order to develop a distributor for small-diameter air conditioner with a best distribution performance, a CFD model was established, and experiments with air and water as working fluids were done to evaluate distribution performance of three types of commonly used distributors. The CFD model was validated by the experiments, the structure of the chosen distributor was optimized, and the optimized distributor was verified by its application in a room air conditioner. The results show that, the jack-type distributor has the best distribution performance, and its uneven index are less than 6% under rated cooling and rated heating conditions; the CFD model can predict the performance of distributors, with the deviation of uneven index less than 15%. The validated CFD model was used to optimize the structure of the jack-type distributor. Application of the optimized distributor shows that it can enhance the energy efficiency of room air conditioner by 2.2%-2.7%.

Documents disponibles

Format PDF

Pages : 93-100

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails


Liens


Voir d'autres articles du même numéro (5)
Voir la source