EVALUATION DE LA PERFORMANCE DES FRIGORIGENES PURS ET EN MELANGE DANS LES REFRIGERATEURS DOMESTIQUES : REMPLACEMENT PROVISOIRE DU R12.

PERFORMANCE EVALUATION OF PURE AND MIXED REFRIGERANTS IN DOMESTIC REFRIGERATORS: DROP-IN REPLACEMENT OF R12.

Résumé

POUR LA SIMULATION D'UN SYSTEME THERMIQUE EN REGIME STABLE, ON A EMPLOYE INDEPENDAMMENT LA METHODE DE SUBSTITUTION SUCCESSIVE ET LA METHODE DE NEWTON-RAPHSON, QUI ONT DONNE LES MEMES RESULTATS SANS AUCUNE DIFFERENCE NOTABLE DE PERFORMANCE. ON A EXAMINE A FOND 15 FRIGORIGENES PURS ET 21 MELANGES. LES RESULTATS ONT INDIQUE QU'AUCUN FLUIDE PUR NE POURRAIT CONSTITUER UN FRIGORIGENE DE RECHANGE POUR LE R12, A CAUSE DE L'INADEQUATION AU NIVEAU DU RENDEMENT VOLUMETRIQUE, MEME SI QUELQUES FLUIDES COMME LE R22, LE R152A, LE R142B, LE R141B ONT UN COP COMPARABLE A CELUI DU R12. SEULS LES MELANGES R22-R142B ET R32-R142B ONT PERMIS D'OBTENIR UNE AUGMENTATION DU COP DE 3 % MAXIMUM, AVEC LA MEME CAPACITE QUE CELLE DU R12. A COURT TERME, CES MELANGES POURRAIENT REMPLACER LE R12.

Détails

  • Titre original : PERFORMANCE EVALUATION OF PURE AND MIXED REFRIGERANTS IN DOMESTIC REFRIGERATORS: DROP-IN REPLACEMENT OF R12.
  • Identifiant de la fiche : 1991-1165
  • Langues : Anglais
  • Date d'édition : 17/07/1990
  • Source : Source : USNC-IIR/Proc. 1990 Refrig. Conf., Purdue Univ./ASHRAE, Purdue CFC Conf./Purdue Univ., Ray W. Herrick Lab., Sch. mech. Eng.
    177-189; 5 fig.; 3 tabl.; 15 ref.