Evaluation de la performance et des changements de composition de mélanges zéotropiques dans un réfrigérateur/congélateur de type Lorenz-Meutzner.

Evaluation of performance and composition shift of zeotropic mixtures in a Lorenz-Meutzner refrigerator/freezer.

Auteurs : BASKIN E., SMITH N. D., DELAFIELD F. R., et al.

Résumé

The paper presents the Lorenz-Meutzner refrigerator/freezer equipped with a 1060 Btu/h compressor, two evaporators, and two intercoolers, that was experimentally tested in an environmental chamber, using several hydrofluoropropane-based zeotropic mixtures. Hydrofluorocarbons R245ca/R152a performed comparably to R134a, R245ca/hydrocarbon R270 (cyclopropane) outperformed all zeotropic mixtures and R134a by at least 12.2 plus or minus 7%. Refrigerant samples taken during refrigerator/freezer operation revealed substantial composition shifts. Lorenz and Meutzner (1975) stated that the following parameters influence the optimum performance of the design: (1) heat exchanger size, (2) capillary tube length, (3) refrigerant charge, and (4) compressor size. This work investigates three of these parameters.

Détails

  • Titre original : Evaluation of performance and composition shift of zeotropic mixtures in a Lorenz-Meutzner refrigerator/freezer.
  • Identifiant de la fiche : 2000-1860
  • Langues : Anglais
  • Source : ASHRAE Transactions. 1999 Winter Meeting, Chicago, Illinois + CD-ROM.
  • Date d'édition : 1999
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (54)
Voir le compte rendu de la conférence