Evaluation des concepts de déshumidification mécaniques. 1.
Evaluation of mechanical dehumidification concepts. 1.
Auteurs : TARAS M. F.
Résumé
In recent years, humidity concerns have gained increasing attention in the air conditioning industry. In part, this increased attention is the result of high indoor air quality standards and newly introduced legislation and industry regulations. Humidity concerns have become even more visible since the introduction of alternate refrigerants with superior thermo-physical properties that may adversely affect system dehumidification capability. Although various dehumidification concepts have found their way into standard equipment offerings, the choice of the system type and configuration is not obvious and entails detailed evaluation of multiple characteristics. This paper analyzes various mechanical reheat/dehumidification concepts and highlights their advantages and drawbacks. The conclusion reached is that the reheat method utilizing a two-phase refrigerant mixture may provide a viable alternative to existing concepts in terms of application coverage and operational flexibility while preserving system functionality and reliability. See also this Bulletin, reference 2007-1691.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of mechanical dehumidification concepts. 1.
- Identifiant de la fiche : 2007-1690
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Date d'édition : 17/07/2006
Liens
Voir d'autres communications du même compte rendu (157)
Voir le compte rendu de la conférence
Indexation
-
Recherche sur la performance de déshumidificati...
- Auteurs : ZHANG H., LI C., LI B.
- Date : 09/2009
- Langues : Chinois
- Source : HV & AC - vol. 39 - n. 228
- Formats : PDF
Voir la fiche
-
PROPOSAL FOR A HYBRID DESICCANT AIR-CONDITIONIN...
- Auteurs : MACLAINE-CROSS I. L.
- Date : 1988
- Langues : Anglais
Voir la fiche
-
DIMENSIONNEMENT DES DESHUMIDIFICATEURS.
- Date : 1987
- Langues : Français
- Source : Rev. Danfoss - vol. 40 - n. 1
Voir la fiche
-
Evaluation of mechanical dehumidification conce...
- Auteurs : TARAS M. F.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Separate sensible and latent cooling in a resid...
- Auteurs : SCHAUS M., HORTON W. T.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche