Évaluation des taux d'infiltration d'air dans des immeubles résidentiels au Portugal.
Assessment of air infiltration rates in residential buildings in Portugal.
Numéro : pap. 1040
Auteurs : GOMES M. R., GAMEIRO DA SILVA M., SIMÕES N.
Résumé
Due to electricity and natural gas consumptions, final energy use in households in Portugal has a significant impact. It has been increasing for the last two decades, against the tendency in most EU countries, representing nowadays 17% of the total final energy use in the country (Eurostat, 2010; 2011). The current Portuguese regulation about thermal performance of buildings, issued in 2006 to put into force the measures established in the European Directive 2002/91 for the Energy Performance of Buildings (EPBD), considers also Indoor Air Quality aspects. In the design phase of residential buildings a minimum infiltration rate of 0,6 air exchanges per hour is considered, but some uncertainty persists about the trueness of this figure in the existing and newly built houses. Due to the efforts carried out to better insulate the envelopes of buildings, the role of air infiltration rates became more important, which justifies the need of a better characterization of the building stock in order to design the strategies to improve energy performance and promote energy savings. Several series of trials were performed using the decay concentration technique in 20 residencies in the Oporto District under regular occupation, using the metabolic CO2 released by the occupants as tracer gas. The results obtained are compared and discussed with those estimated by the methodology of the current national thermal code for residential buildings.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Assessment of air infiltration rates in residential buildings in Portugal.
- Identifiant de la fiche : 30010457
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Mesure; Renouvellement d'air; Portugal; Performance; Immeuble d'habitation
-
VENTILATION AND AIR TIGHTNESS IN LOW-RISE RESID...
- Auteurs : BLOMSTERBERG A.
- Date : 1990
- Langues : Anglais
- Source : Swed. Counc. Build. Res. - CBR D10:1990; 221 p.
Voir la fiche
-
AIR CHANGE RATES IN SWEDISH DWELLINGS 1974-88.
- Auteurs : LYBERG M. D., BOMAN C. A., SKOGBERG S.
- Date : 01/08/1989
- Langues : Anglais
Voir la fiche
-
VERS UNE MEILLEURE QUALITE DE L'AIR.
- Auteurs : CADIERGUES R.
- Date : 12/1991
- Langues : Français
- Source : Chaud Froid Plomb. - n. 531
Voir la fiche
-
Use of contaminants for evaluation of ventilati...
- Auteurs : HAYAKAWA S., TAKEMASA Y.
- Date : 15/06/1994
- Langues : Anglais
- Source : ROOMVENT '94. Air distribution in rooms. Proceedings.
Voir la fiche
-
THE PERFORMANCE OF VENTILATION IN RESIDENTIAL B...
- Auteurs : RUOTSALAINEN R.
- Date : 01/08/1989
- Langues : Anglais
Voir la fiche