Document IIF
Évaluation du taux de fuite et de la durabilité des joints mécaniques réalisés sur le terrain pour les systèmes utilisant des frigorigènes inflammables à faible GWP (ASHRAE RP-1808).
Assessment of leakage rate and durability of field-made mechanical joints for systems using low-GWP flammable refrigerants (ASHRAE RP-1808).
Numéro : pap. n. 1115
Auteurs : LAWRENCE N., RAJ S., ELBEL S.
Résumé
The conversion of refrigeration and air-conditioning systems to low-GWP refrigerants, such as HFOs, has raised many concerns about the flammability of potential replacement refrigerants, particularly regarding the potential leakage of flammable refrigerant from mechanical joints. This paper presents the results of a study investigating the durability and leakage rate of different types of field-made joints used in refrigeration and air-conditioning systems, focusing on flame-free joining methods and systems with flammable refrigerants. Three different types of fittings were investigated: Press/crimp fittings, compression fittings, and flare fittings. For each type of fitting, two different sizes were used as well as two different tubing materials (copper and aluminum). Brazed joints were also investigated as a baseline. Durability testing in the form of pressure-temperature thermal cycling, freeze-thaw cycling, and vibration testing was performed on all combinations of fittings. Refrigerant leakage rates were also determined for all combinations of fittings.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Assessment of leakage rate and durability of field-made mechanical joints for systems using low-GWP flammable refrigerants (ASHRAE RP-1808).
- Identifiant de la fiche : 30024819
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1115
Liens
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Assessment of leakage rate and durability of fi...
- Auteurs : LAWRENCE N., RAJ S., ELBEL S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Assessment of leakage rate and durability of fi...
- Auteurs : ELBEL S., LAWRENCE L., RAJ S.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Détection de fuites et tests d'étanchéité.
- Auteurs : SCHNERR T., SEIDEL R.
- Date : 2016
- Langues : Français
- Source : Cool & Comfort
Voir la fiche
-
HFO leak detection technologies and strategies ...
- Auteurs : BURNISTON T.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
HFO leak detection technologies and strategies ...
- Auteurs : BURNISTON T.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche