Document IIF
Évaluation expérimentale d’un climatiseur split fonctionnant au R-417A sous différentes conditions intérieures et extérieures.
Experimental assessment of a split air conditioner working with R-417A under different indoor and outdoor conditions.
Auteurs : ELGENDY E., MELIKE M., FATOUH M.
Type d'article : Article, Article de la RIF
Résumé
The present paper aims to evaluate the performance characteristics of a split air conditioner working with R-417A under different indoor and outdoor operating conditions. A test facility was constructed and experiments were carried out to achieve the research objectives. The indoor conditions were varied in a wide range of air temperature (21–31.4?°C), air relative humidity (40.3%–61.9%) and air velocity (2.8–4.7?m?s-1) while the outdoor conditions were changed in range of air temperature (35–51.2?°C) and air relative humidity (40.8%–81.2%). Experimental results showed that the increase in the indoor air temperature causes an enhancement in the system coefficient of performance by about 59.7%, while increasing the outdoor air temperature decreases the system coefficient of performance by about 51.6%. The system cooling capacity using R-417A was lower than that of R-22 by about 33.2% at indoor air temperature of 24.5?°C.
Documents disponibles
Format PDF
Pages : 268-281
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental assessment of a split air conditioner working with R-417A under different indoor and outdoor conditions.
- Identifiant de la fiche : 30022866
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Date d'édition : 01/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.10.005
Liens
Voir d'autres articles du même numéro (36)
Voir la source
Indexation
-
Thèmes :
Autres équipements de conditionnement d'air;
HFC - Mots-clés : Système split; Conditionneur d'air; Performance; R417a; Humidité relative; Experimentation
-
Thermodynamic performance of air conditioners w...
- Auteurs : ORUÇ V., DEVECIOGLU A. G.
- Date : 07/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 55
- Formats : PDF
Voir la fiche
-
Experimental comparison of the energy parameter...
- Auteurs : ORUÇ V., DEVECIOGLU A. G., BERK U., et al.
- Date : 03/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 63
- Formats : PDF
Voir la fiche
-
ESTABLISHMENT OF PERFORMANCE CHARTS OF AN AIR C...
- Auteurs : GAO F. S.
- Date : 1983
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 6 - n. 2
- Formats : PDF
Voir la fiche
-
A HUMIDITY DETECTION METHOD FOR USE WITH A ROOM...
- Auteurs : KUWAHARA E.
- Date : 1985
- Langues : Anglais
Voir la fiche
-
Tendances constatées dans le domaine de la conc...
- Auteurs : KARPIS E. E.
- Date : 1994
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 3
Voir la fiche