Auteurs : ELGENDY E., MELIKE M., FATOUH M.

Type d'article : Article, Article de la RIF

Résumé

The present paper aims to evaluate the performance characteristics of a split air conditioner working with R-417A under different indoor and outdoor operating conditions. A test facility was constructed and experiments were carried out to achieve the research objectives. The indoor conditions were varied in a wide range of air temperature (21–31.4?°C), air relative humidity (40.3%–61.9%) and air velocity (2.8–4.7?m?s-1) while the outdoor conditions were changed in range of air temperature (35–51.2?°C) and air relative humidity (40.8%–81.2%). Experimental results showed that the increase in the indoor air temperature causes an enhancement in the system coefficient of performance by about 59.7%, while increasing the outdoor air temperature decreases the system coefficient of performance by about 51.6%. The system cooling capacity using R-417A was lower than that of R-22 by about 33.2% at indoor air temperature of 24.5?°C.

Documents disponibles

Format PDF

Pages : 268-281

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental assessment of a split air conditioner working with R-417A under different indoor and outdoor conditions.
  • Identifiant de la fiche : 30022866
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
  • Date d'édition : 01/2018
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.10.005