Document IIF

Evaluation expérimentale d'un éjecteur utilisé pour recirculer l'ammoniac liquide dans un système avec un évaporateur à plaques suralimenté.

Experimental evaluation of an ejector as liquid re-circulator in an overfeed NH3 system with a plate evaporator.

Auteurs : DOPAZO J. A., FERNÁNDEZ-SEARA J.

Type d'article : Article, Article de la RIF

Résumé

This paper deals with the experimental performance evaluation of an ejector, linked to a manual expansion valve, working as a liquid re-circulator component in an overfeed NH3 plate evaporator. The evaporator was tested in a single stage system belonging to a cascade refrigeration system prototype. The evaporator is an ALFANOVA HP76 plate heat exchanger with 50 plates. A Phillips ejector with a 1/2? diameter throat and 1.4 mm diameter nozzle was used. The recirculation rate was experimentally determined for different operating conditions. Experimental data are reported for volumetric flow rate at the manual expansion valve inlet from 0.8 to 1.6 l/min, evaporating pressure from 0.14 to 0.22 MPa and condensing pressure from 0.85 to 1 MPa. The experimental result showed recirculation rates between 2 and 4. The evaporating capacity varied from 9.48 to 18.37 kW. In addition, another two nozzles were tested and the results are also presented and discussed.

Documents disponibles

Format PDF

Pages : 1676-1683

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental evaluation of an ejector as liquid re-circulator in an overfeed NH3 system with a plate evaporator.
  • Identifiant de la fiche : 30001680
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 7
  • Date d'édition : 11/2011

Liens


Voir d'autres articles du même numéro (18)
Voir la source