Evaluation expérimentale et simulation des effets de la circulation d'huile dans un système de conditionnement d'air à vitesse variable au R-22 et au R-407C.
Simulation and experimental evaluation of the effects of oil circulation in an inverter air conditioning system using R-22 and R-407C.
Auteurs : SARNTICHARTSAK P., MONYAKUL V., THEPA S., et al.
Type d'article : Article
Résumé
A steady-state mathematical modelling and experimental study were carried out to investigate effects of oil circulation in an inverter air conditioner using R-22 and R-407C. To highlight the prediction of oil circulating mass fraction, the simplified sub-model of oil discharge was modified. The predicted results were validated with experimental data. Two tested lubricants were mineral oil (MO) and polyol-ester lubricant. The experiments varied the compressor frequency in the range of 30-50 Hz for each compressor oil level (0.8 and 1 L). The results showed that the circulating oil flow rates decreased with the reducing compressor frequency and with a lower oil charge. The lubricant concentration affected the system performance at high frequencies. The charged oil quantity of 0.8 l provided more efficient performance than 11. The vapour velocity of R-407C is inadequate high enough to entrain the liquid MO at its lowest frequency. The immiscible mixture of R-407C/MO is not suitable used in the inverter air conditioning system. The proposed model obtains better resultsfor the miscible mixture. The model prediction agreed with the measured values in the compressor frequency of 40-50 Hz. [Reprinted with permission from Elsevier. Copyright, 2006].
Détails
- Titre original : Simulation and experimental evaluation of the effects of oil circulation in an inverter air conditioning system using R-22 and R-407C.
- Identifiant de la fiche : 2007-0326
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 14-15
- Date d'édition : 10/2006
Liens
Voir d'autres articles du même numéro (9)
Voir la source
Indexation
-
Matériel de climatisation à vitesse variable.
- Auteurs : BENSAFI A., HANTZ D., MONDOT M.
- Date : 01/2004
- Langues : Français
- Source : Rev. gén. Froid - vol. 94 - n. 1040
Voir la fiche
-
Development of a highly efficient air-condition...
- Auteurs : MORIMOTO O., KASAI T., KOGE H., et al.
- Date : 04/12/2002
- Langues : Anglais
- Source : Green breeze from Asia: frontiers of refrigerants, heat transfer and system.. ACRA-2002. Proceedings of the Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Calcul théorique et recherche sur l'application...
- Auteurs : DU K., DAI G. M.
- Date : 06/2003
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 24 - n. 96
- Formats : PDF
Voir la fiche
-
Wide range unsteady-state simulation of compres...
- Auteurs : OHNO K., NAKAMURA H., SAITO K.
- Date : 18/09/2008
- Langues : Anglais
- Source : HVAC Energy Efficiency Best Practice Conference
- Formats : PDF
Voir la fiche
-
Some modelling improvements for unitary air con...
- Auteurs : SHEN B., BRAUN J. E., GROLL E. A.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche