Experimental cabinet-boundary energy and exergy analysis of a cabinet-integrated direct-expansion refrigeration system for data center applications.
Auteurs : TIKTAS A., ERKEK T. Ü.
Type d'article : Article de la RIF
Résumé
Cabinet-integrated direct-expansion (DX) refrigeration is increasingly adopted for high-density server racks; however, its thermodynamic effectiveness remains insufficiently characterized because conventional coefficient of performance (COP) metrics do not resolve cabinet-side irreversibilities, airflow penalties, or humidity-driven latent effects. This study applies a cabinet-boundary moist-air exergy framework to a 10 kW split DX rack integrated system, defining the useful cooling product at the supply–return air interface and explicitly ac counting for cabinet fan power. Experimental evaluation of 24 steady-state cases, covering two refrigerants (R410A and R454B), two IT heat loads (6 and 9 kW), and inverter-driven part-load operation, yields COP values of 2.18–4.73 and cabinet-boundary exergy efficiencies of 0.35–0.75, revealing a pronounced non-monotonic COP–ηₑₓ relationship. Component-resolved analysis identifies the compressor and cabinet-integrated evapo rator as the dominant sources of irreversibility, accounting on average for approximately 50 % and 33 % of total exergy destruction, respectively. Elevated return-air humidity increases evaporator exergy destruction by 8–12 %, a penalty not captured by COP-based evaluation. A multi-objective Pareto–TOPSIS analysis identifies Case 22 (R454B, 9 kW, 4692 rpm) as the optimal compromise between energy efficiency and thermodynamic effec tiveness. The results establish cabinet-boundary moist-air exergy analysis as a physically grounded and experi mentally validated diagnostic framework for design and control optimization of rack-integrated DX systems.
Documents disponibles
Format PDF
Pages : 18
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental cabinet-boundary energy and exergy analysis of a cabinet-integrated direct-expansion refrigeration system for data center applications.
- Identifiant de la fiche : 30034928
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 187
- Date d'édition : 07/2026
- DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2026.106924
Liens
Voir d'autres articles du même numéro (35)
Voir la source
-
Direct-expansion refrigeration vs chilled water.
- Auteurs : JORDAN C. H.
- Date : 10/1991
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 63 - n. 10
Voir la fiche
-
CLIMATISATION DES SALLES INFORMATIQUES. MICRO E...
- Auteurs : KEIFLIN J.
- Date : 1986
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - vol. 40 - n. 622
Voir la fiche
-
ECONOMIE D'ENERGIE DANS LES INSTALLATIONS DE CO...
- Auteurs : CATTANEO P.
- Date : 1985
- Langues : Italien
- Source : Install. ital. - vol. 36 - n. 11
Voir la fiche
-
COMPUTER ROOM COOLING: REMOTE EQUIPMENT WITH OV...
- Auteurs : WATSON G. R.
- Date : 05/1984
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 56 - n. 5
Voir la fiche
-
Recherches sur les économies d'énergie applicab...
- Auteurs : QIAN X., LI Z.
- Date : 03/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 261
- Formats : PDF
Voir la fiche