Expérimentation : prérefroidissement à circulation naturelle dans un système à pompe cryogénique.

Natural circulation precooling experiment on a cryogenic pump system.

Auteurs : ZHENG X., CHEN G., GAN Z., et al.

Résumé

To cool down a cryogenic pump system effectively from room temperature to a cryogenic temperature, a natural circulation system is introduced. In this system, the liquid nitrogen is discharged from a liquid nitrogen vessel and goes through the cryogenic pump, then flows in a circle via the reflux pipe back to the vessel. The experimental apparatus is illustrated and the test process is described. Heat transfer and pressure drop during the cool-down process is portrayed in the figures. The experimental results demonstrate that natural circulation is an efficient way to precool the pump system and maintain it at cryogenic temperatures.

Détails

  • Titre original : Natural circulation precooling experiment on a cryogenic pump system.
  • Identifiant de la fiche : 2006-1067
  • Langues : Anglais
  • Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
  • Date d'édition : 22/04/2003

Liens


Voir d'autres communications du même compte rendu (166)
Voir le compte rendu de la conférence