Expérimentation sur un réfrigérateur à régénération et adsorption continues de chaleur en utilisant des échangeurs de chaleur à plaques en spirale comme absorbeurs.

Experiment on a continuous heat regenerative adsorption refrigerator using spiral plate heat exchanger as adsorbers.

Auteurs : WANG R. Z., WU J. Y., XU Y. X., TENG Y., SHI W.

Type d'article : Article

Résumé

Spiral plate heat exchangers were proposed to be used as adsorbers, and a prototype heat regenerative adsorption refrigerator using the activated carbon-methanol pair was developped and tested. The adsorption system using 12 kg activated carbon has a cycle time of 40 minutes, meanwhile 14 kg ice per day was made.

Détails

  • Titre original : Experiment on a continuous heat regenerative adsorption refrigerator using spiral plate heat exchanger as adsorbers.
  • Identifiant de la fiche : 1999-0143
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 18 - n. 1-2
  • Date d'édition : 01/1998

Liens


Voir d'autres articles du même numéro (1)
Voir la source