Facteur de risque de contamination dans une salle blanche détériorée.
Contamination risk factor of a damaged clean room.
Numéro : pap. 1075
Auteurs : ZAMANKHAN P.
Résumé
Contamination risk factor (CRF) quantifies the effectiveness of a barrier device such as a single door in preventing the migration of airborne particles into a cleanroom. This article describes simulations of a damaged cleanroom at the University of Iceland to assess its decontamination effectiveness. The fluid flow equations are solved using the Lattice-Boltzmann method with the Bhatnagar-Gross-Krook (BGK) operator for collisions. The airborne particles are assumed to be spherical with a radius very large compared with the radius of the air molecules and collisions between the particles and the air molecules to be completely elastic. It is shown that due to the damage, the CRF level is quite high. This observation indicates that the quality of the items manufactured in the damaged cleanroom at the University of Iceland is highly questionable.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Contamination risk factor of a damaged clean room.
- Identifiant de la fiche : 30010480
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d’air dans les laboratoires et l’industrie
- Mots-clés : Contamination; Ventilation; Simulation; Salle blanche
-
NUMERICAL AND EXPERIMENTAL STUDY ON TURBULENT D...
- Auteurs : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Langues : Anglais
Voir la fiche
-
ETUDE DE LA REPARTITION DE LA VITESSE DE L'AIR ...
- Auteurs : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 37
Voir la fiche
-
ETUDE DE LA REPARTITION DE LA VITESSE DE L'AIR ...
- Auteurs : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 37
Voir la fiche
-
ETUDE SUR LA DISTRIBUTION DE LA VITESSE DE L'AI...
- Auteurs : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1989
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 40
Voir la fiche
-
LA CONCEPTION DES SALLES A ENVIRONNEMENT CONTRO...
- Auteurs : ROSSET R., ROSSET P.
- Date : 06/1991
- Langues : Français
- Source : Rev. gén. Froid - vol. 81 - n. 5
Voir la fiche