Document IIF

Génération d'entropie pendant l'ébullition de frigorigènes synthétiques.

Entropy generation during flow boiling of synthetic refrigerants.

Auteurs : REVELLIN R., BONJOUR J.

Résumé

In general, enhanced tubes are used in evaporators in order to increase their heat transfer performances. Enhanced tubes also induce an increase of the pressure drop along the evaporator and, as a consequence, the decrease of the saturation temperature is higher than that observed with smooth tubes. An important question is therefore: "Are enhanced tubes thermodynamically always better than smooth tubes?" In order to answer this question, the relations (using the separated and the mixture models) developed by Revellin et al. (2009) for calculating the local entropy generation of a diabatic two-phase flow have been applied to an evaporator. Its length is fixed to 5 m; the fluid is R134a. The heat flux is assumed uniform along the evaporator and both smooth and enhanced tubes have been considered. It appears that enhanced tubes are not always thermodynamically the best solution. Furthermore, reducing the tube diameters seems to be a good solution for reducing entropy generation and, as a consequence, for reducing the refrigerant charge.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Entropy generation during flow boiling of synthetic refrigerants.
  • Identifiant de la fiche : 2009-1462
  • Langues : Anglais
  • Source : RCR 2009. 1st IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems.
  • Date d'édition : 06/04/2009

Liens


Voir d'autres communications du même compte rendu (26)
Voir le compte rendu de la conférence