Hygiène dans les systèmes de chauffage, de ventilation et de conditionnement d'air : résultats d'un essai sur site de grande ampleur.
Hygiene in HVAC systems: results of a large field test.
Numéro : pap. 94
Auteurs : SICRE B.
Résumé
The guideline SWKI VA104-01 „hygiene requirements for ventilation and air-conditioning systems and units“ is the current code of practice in Switzerland and provides a list of requirements in terms of hygiene regarding the design, construction, operation and maintenance of ventilation systems. This paper describes a research project aiming at drawing a general picture of the current hygiene situation of HVAC systems across Switzerland, using the guideline as a yard stick. A secondary goal of the project was to check how feasible this guideline is in the real world. In total, 100 ventilation and air conditioning systems in different kinds of buildings were examined in the project. Hygienic state of the plant parts (i.e. filter, cooler, humidifier, ventilator chamber…) were assessed by visual inspection (dust deposit, biofilms…) and by taking microbiological samples. The samples (air, surface, humidifier water) were examined in a laboratory for germs. In addition, the system operators were interviewed to find out more about the routine maintenance and cleaning of the HVAC system for correlations with lab results. The anonymously kept results were evaluated in the context of a statistical study. On this basis recommendations for improvement in terms of planning, erection, operation and maintenance were worked out and submitted to associations of professionals and health care authorities. Differently from earlier published papers, this paper is going to focus more on cross-evaluations, especially looking at influence of filter class, age of installation, frequency of maintenance, outdoor pollution level… on hygiene state of HVAC system.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Hygiene in HVAC systems: results of a large field test.
- Identifiant de la fiche : 30008600
- Langues : Anglais
- Sujet : Réglementation
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
Control of substances hazardous to health regul...
- Date : 1995
- Langues : Anglais
- Source : Health Saf. Comm., HSE - 74 p.
Voir la fiche
-
Norme gouvernant la conception de base à l'égar...
- Auteurs : KAGAWA J.
- Date : 03/1998
- Langues : Japonais
- Source : SHASE - vol. 72 - n. 3
Voir la fiche
-
European Natvent project completed.
- Auteurs : KUKADIA V., PERERA E.
- Date : 03/1999
- Langues : Anglais
- Source : Air Infiltration Rev. - vol. 20 - n. 2
Voir la fiche
-
Efficacy of intermittent ventilation for provid...
- Auteurs : SHERMAN M. H.
- Date : 2006
- Langues : Anglais
- Source : ASHRAE Transactions. 2006 Winter Meeting. Volume 112, part 1 + CD-ROM.
Voir la fiche
-
La qualité de l'air soufflé : ventilation, clim...
- Auteurs : CAUCHEPIN J. L.
- Date : 2004
- Langues : Français
Voir la fiche