Résumé
The viscosity of oil, miscibility with refrigerant, thermal stability and compatibility with motor materials, etc. are to be considered. Furthermore, by reason of the fact that POEs are more hygroscopic than mineral oils, hydrolytic stability and hygroscopicity of the selected oil must be considered seriously. The paper describes how to develop a rotary compressor using R407C and some essential factors that should be considered. After 2000 hours durability test, conclusions are drawn. Because of the hygroscopicity of POE and the differences between R407C and R22 applications, some changes ought to be made in the compressor assembly line.
Détails
- Titre original : Influence of lubricant on rotary compressor using R407C.
- Identifiant de la fiche : 2001-1809
- Langues : Anglais
- Source : Proceedings of the 2000 International Compressor Engineering Conference at Purdue.
- Date d'édition : 25/07/2000
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
Lubrifiants;
Mélanges - Mots-clés : R407C; Lubrifiant; Frigorigène; Compresseur rotatif; Compresseur
-
Développement d'un compresseur rotatif utilisan...
- Auteurs : SHIRAFUJI Y., KATO T., IZAWA T., et al.
- Date : 26/11/1998
- Langues : Japonais
- Source : Proceedings of the International symposium on HCFC alternative refrigerants '98: latest technology for higher performance and higher efficiency air conditioning and refrigeration equipment to the 21st century.
Voir la fiche
-
New immiscible refrigeration lubricant for HFCs.
- Auteurs : SUNAMI M., TAKIGAWA K., SUDA S., SASAKI U.
- Date : 24/06/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
The effect of water contents of POE on scuffing...
- Auteurs : NAKAO H., MATSUKAWA K., SHIRAFUJI Y., et al.
- Date : 25/07/2000
- Langues : Anglais
- Source : Proceedings of the 2000 International Compressor Engineering Conference at Purdue.
Voir la fiche
-
Evaluation de la performance et de la fiabilité...
- Auteurs : FUJIWARA K., MATSUMOTO K., NISHIKAWA T., et al.
- Date : 26/11/1998
- Langues : Japonais
- Source : Proceedings of the International symposium on HCFC alternative refrigerants '98: latest technology for higher performance and higher efficiency air conditioning and refrigeration equipment to the 21st century.
Voir la fiche
-
Experimental comparison on performance of rotar...
- Auteurs : YU H. L., LI R. Y., CHEN D. K.
- Date : 24/06/1995
- Langues : Anglais
- Source : ASHRAE Transactions.