Jet refroidissant un cylindre : hauteur optimale de la fente.

Optimal slot height in the jet cooling of a circular cylinder.

Auteurs : GORI F., BOSSI L.

Type d'article : Article

Résumé

Experimental results are presented for heat transfer cooling of an electrically heated circular cylinder, of diameter D= 10 mm, by a slot jet, of height S= 2.5 mm, i.e. with D/S= 4. Mean and local Nusselt numbers are presented versus the Reynolds numbers, the distance of the cylinder from the slot exit, H, and the angle from the impinging point. Comparisons have been done among the mean Nusselt numbers of this work and previous experimental results of the same authors, carried out with diameter to slot height ratios equal to D/S=1 and 2. The conclusion is that the mean Nusselt number, defined as NumD= hmD/k, is higher for D/S= 4, versus the Reynolds number, defined as ReD= WD/v. On the contrary, the mean Nusselt number, defined on the basis of the slot height, NumS= hmS/k, has similar values, for the different slot heights, versus the Reynolds number, defined as ReS= WS/v, with the trend of higher results for the slot with D/S= 2.

Détails

  • Titre original : Optimal slot height in the jet cooling of a circular cylinder.
  • Identifiant de la fiche : 2003-2175
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 23 - n. 7
  • Date d'édition : 05/2003