L'INFLUENCE DE LA CHARGE EN FRIGORIGENE SUR LE FONCTIONNEMENT DE PETITS APPAREILS FRIGORIFIQUES.

THE INFLUENCE OF THE REFRIGERANT CHARGE ON THE FUNCTIONING OF SMALL REFRIGERATING APPLIANCES.

Résumé

LA TEMPERATURE AMBIANTE DETERMINE LA TEMPERATURE DE CONDENSATION ET LA CHARGE THERMIQUE DE L'EVAPORATEUR QUI, A LEUR TOUR, DETERMINENT LA VALEUR OPTIMALE DE LA CHARGE. ON PRESENTE UNE CORRELATION DE FRACTION DE VIDE POUR LA DESCRIPTION DE CONDITIONS D'ECOULEMENT DIPHASIQUE, ET ON COMPARE CETTE CORRELATION AVEC LES MESURES. ON UTILISE ENSUITE CE MODELE DE FRACTION DE VIDE POUR L'ANALYSE NUMERIQUE A REGIME STABLE D'UN APPAREIL. LA CAPACITE DU TUBE CAPILLAIRE AINSI QUE LA STRATEGIE DE REGULATION S'AVERENT ETRE EGALEMENT DES PARAMETRES IMPORTANTS POUR LA DETERMINATION DE LA CHARGE OPTIMALE EN FRIGORIGENE. ON DONNE DES RECOMMANDATIONS, QUANT AUX COMPOSANTS, POUR LES CAS OU L'APPAREIL DOIT FONCTIONNER DANS UNE LARGE GAMME DE TEMPERATURES AMBIANTES AVEC UNE CHARGE FIXE EN FRIGORIGENE.

Détails

  • Titre original : THE INFLUENCE OF THE REFRIGERANT CHARGE ON THE FUNCTIONING OF SMALL REFRIGERATING APPLIANCES.
  • Identifiant de la fiche : 1989-2272
  • Langues : Anglais
  • Date d'édition : 1988
  • Source : Source : ASHRAE Trans.
    vol. 94; n. 2; 813-828; 11 fig.; 1 tabl.; 11 ref.; discuss.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.