LA CHARGE EN FRIGORIGENE DANS LES PETITS APPAREILS : INFLUENCE DE L'ECHANGEUR DE CHALEUR A CAPILLAIRE/CONDUITE D'ASPIRATION.

REFRIGERANT CHARGE IN SMALL APPLIANCES: INFLUENCE OF THE CAPILLARY/SUCTION LINE HEAT EXCHANGER.

Résumé

ON DECRIT L'INFLUENCE DE LA CHARGE EN FRIGORIGENE ET DE LA CAPACITE DU TUBE CAPILLAIRE SUR LA PERFORMANCE D'UN APPAREIL FRIGORIFIQUE CONTROLE DE FACON CONTINUE. DES MESURES ET DES CALCULS DE LA CHARGE EN FRIGORIGENE NECESSAIRE ONT ETE EFFECTUES POUR UNE CONFIGURATION SANS ECHANGEUR DE CHALEUR INTERIEUR. UN MODELE DE FRACTION DE VIDE EST RETENU D'APRES UNE COMPARAISON DES RESULTATS : L'OPTIMISATION DU CAPILLAIRE DOIT ETRE PREFERE A LA REGULATION SUR UNE LARGE PLAGE AMBIANTE SI UNE CHARGE FIXE EN FRIGORIGENE EST APPLIQUEE SANS UTILISER UN ECHANGEUR DE CHALEUR INTERIEUR. LA NECESSITE D'UNE OPTIMISATION PRECISE DU TUBE CAPILLAIRE EST ETUDIEE NUMERIQUEMENT EN SUPPOSANT QUE L'ECHANGEUR DE CHALEUR EST MIS EN OEUVRE DANS LE SYSTEME.