Document IIF

La pompe à chaleur à entraînement thermique.

A thermally actuated heat pump.

Auteurs : EDER F. X.

Type d'article : Article, Article de la RIF

Résumé

A new kind of heat pump is described derived from the Vuilleumier process which has been known since 1918 but not applied until 1960 for small refrigerators down to 80 K. It consists of two oscillating displacers connected 90° out of phase and in parallel with thermal regenerators. It is pressurized by helium or hydrogen gas to 30-60 bars (3-6x108 N m-2) and runs at 750 to 1500 rpm. The calculated heating power for a model of 1000 cm3 swept volume, taking heat in at 500°C and allowing for losses, will be 4 to 6 kW and a COP between 1.6 and 2.

Documents disponibles

Format PDF

Pages : 86-90

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A thermally actuated heat pump.
  • Identifiant de la fiche : 30001016
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 5 - n. 2
  • Date d'édition : 03/1982