La vascularisation pour le refroidissement et la résistance mécanique.

Vascularization for cooling and mechanical strength.

Auteurs : CETKIN E., LORENTE S., BEJAN A.

Type d'article : Article

Résumé

In this paper the authors explore the use of vascular design that provides cooling and mechanical strength at the same time. They illustrate the concept with a circular plate vascularized with embedded channels. The cooling fluid enters to the plate from the center or from the rim, and leaves after it cools the plate down to an allowable temperature level. The vascular cooling channels also affect the mechanical strength of the plate. The authors simulated numerically the thermofluid and mechanical behavior for three different structures; radial, dendrites with one pairing level and dendrites with two pairing levels. They found that for a given set of conditions (applied pressure difference, coolant inlet position, and number of the cooling channels) there is one configuration that is best; however, there is no single configuration that is best for all conditions. [Reprinted with permission from Elsevier. Copyright, 2011.]

Détails

  • Titre original : Vascularization for cooling and mechanical strength.
  • Identifiant de la fiche : 30003334
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 54 - n. 13-14
  • Date d'édition : 06/2011
  • DOI : http://dx.doi.org/10.1016/j.ijheatmasstransfer.2011.02.061

Liens


Voir d'autres articles du même numéro (3)
Voir la source