Document IIF
Les effets de différentes combinaisons de frigorigènes sur la performance d' un système frigorifique à compression de vapeur muni d'un dispositif de sous-refroidissement mécanique.
The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical sub-cooling.
Auteurs : QURESHI B. A., ZUBAIR S. M.
Type d'article : Article, Article de la RIF
Résumé
Performance characteristics due to use of different refrigerant combinations in vapor compression cycles with dedicated mechanical sub-cooling are investigated. For scratch designs, R134a used in both cycles produced the best results in terms of COP, COP gain and relative compressor sizing. In retrofit cases, considering the high sensitivity of COP to the relative size of heat exchangers in the sub-cooler cycle and the low gain in COP obtained due to installation of a dedicated sub-cooling cycle when R717 is the main cycle refrigerant, it seems that dedicated mechanical sub-cooling may be more suited to cycles using R134a as the main cycle refrigerant rather than R717. With R134a as the main cycle refrigerant, no major difference was noted, by changing the sub-cooler cycle refrigerant, in the degradation of the performance parameters such as COP and cooling capacity, due to equal fouling of the heat exchangers.
Documents disponibles
Format PDF
Pages : 47-57
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical sub-cooling.
- Identifiant de la fiche : 30003187
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 1
- Date d'édition : 01/2012
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Effect of the condenser subcooling on the perfo...
- Auteurs : POTTKER G., HRNJAK P.
- Date : 02/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 50
- Formats : PDF
Voir la fiche
-
Effect of condenser subcooling of the performan...
- Auteurs : POTTKER G., HRNJAK P.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
The influence of refrigerant subcooling on syst...
- Auteurs : Güntner
- Date : 2010
- Langues : Anglais
Voir la fiche
-
Experimental investigation of the effect of con...
- Auteurs : POTTKER G., HRNJAK P.
- Date : 02/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 50
- Formats : PDF
Voir la fiche
-
Potential for improving efficiency by controlli...
- Auteurs : XU L., HRNJAK P.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF