MESURE DE LA CONCENTRATION D'UN MELANGE HUILE-FRIGORIGENE EN ECOULEMENT A L'AIDE D'UN VISCOSIMETRE DE TYPE A BIPASSE.

MEASURING THE CONCENTRATION OF A FLOWING OIL-REFRIGERANT MIXTURE WITH A BYPASS VISCOMETER.

Résumé

ON A EVALUE UN NOUVEAU VISCOSIMETRE DE TYPE A BIPASSE COMME DETECTEUR POUR MESURER LA CONCENTRATION D'HUILEDANS LA CONDUITE LIQUIDE D'UN SYSTEME FRIGORIFIQUE. ON A EFFECTUE DES ESSAIS SUR LE VISCOSIMETRE DANS DES CONDITIONS SIMULEES DE LA CONDUITE DE LIQUIDE AVEC LES MELANGES SUIVANTS : R12-HUILE NAPHTHENIQUE, R22-HUILE NAPHTHENIQUE ET R502-HUILE ALKYLBENZENE, AVEC DES CONCENTRATIN AA LES TEMPERATURES D'ESSAI DANS LA CONDUITE DE LIQUIDE SIMULEE ALLAIENT DE 294 A 319 K (21 A 46 DEG C) A DES PRESSIONS CORRESPONDANT A UN SOUS-REFROIDISSEMENT DE 1,7 K (1,7 DEG C) APPROXIMATIVEMENT. L'ANALYSE STATISTIQUE DES DONNEES A MONTRE QUE LE VISCOSIMETRE POUVAIT ETRE UTILISE POUR MESURER LA CONCENTRATION D'HUILE EN ECOULEMENT AVEC UNE MARGE D'ERREURS ADMISES DE PLUS OU MOINS 1 A 2 %.

Détails

  • Titre original : MEASURING THE CONCENTRATION OF A FLOWING OIL-REFRIGERANT MIXTURE WITH A BYPASS VISCOMETER.
  • Identifiant de la fiche : 1989-2171
  • Langues : Anglais
  • Date d'édition : 1988
  • Source : Source : ASHRAE Trans.
    vol. 94; n. 2; 588-601; 11 fig.; 1 tabl.; 7 ref.; discuss.