Document IIF
Mesure de la tension superficielle des frigorigènes à faible GWP.
Surface tension measurement of low gwp refrigerants.
Numéro : pap. TP-071
Auteurs : MATSUZONO T., KONDOU C., HIGASHI Y., et al.
Résumé
HFOs (hydro-fluoro-olefins) are very recently under consideration as a potential candidate of R410A alternatives with GWP of 2800 that is most widely used in air-conditioning and refrigeration systems. The capillary constant and surface tension of R32, R1234ze(E), and their binary mixture R32/R1234ze(E) are measured in the temperature range from 274 K to 342 K by the differential capillary rise method. The propagated uncertainty in the surface tension is estimated within 0.3 mN m-1. The experimentally quantified surface tensions of the components R32 and R1234ze(E) well agree with the calculated value by REFPROP 9.1. The measured surface tension of R32/R1234ze(E) at charged compositions 51/49 mass% and 43/57 mass% reasonably agree with the correlation for R32/R1234ze(E) (50/50 mass%) proposed by Tanaka and Higashi [1]. The surface tension data presented in this study and available in literatures (Tanaka and Higashi [1]; Cui et al. [2]) appear to vary almost linearly against mole fraction at a fixed reduced temperature.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Surface tension measurement of low gwp refrigerants.
- Identifiant de la fiche : 30021501
- Langues : Anglais
- Source : 5th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants.
- Date d'édition : 23/04/2017
- DOI : http://dx.doi.org/10.18462/iir.tptpr.2017.0071
Liens
Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Mesures thermodynamiques;
HFC - Mots-clés : R410A; Faible GWP; Tension superficielle; R32; R1234ze(E); Substitut; Mélange; HFO; Experimentation
-
Surface tension of low GWP refrigerant mixtures.
- Auteurs : TANAKA K., TAKAHASHI K., KOBAYASHI K., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Surface tension measurement of low GWP refriger...
- Auteurs : KONDOU C., MATSUZONO T., HIGASHI Y.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Molecular simulation for surface tension of new...
- Auteurs : HOURIEZ C., MASELLA M., KONDOU C., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Surface tension and parachor for a new low-GWP ...
- Auteurs : LIU Y., KONDOU C., COQUELET C., HOURIEZ C.
- Date : 12/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 132
- Formats : PDF
Voir la fiche
-
Sviluppi sullo scambio termico con refrigeranti...
- Auteurs : AZZOLIN M., BORTOLIN S., CAVALLINI A., et al.
- Date : 2017
- Langues : Italien
- Source : Industria & Formazione - vol. 41 - n.408
- Formats : PDF
Voir la fiche