MESURES DE K POUR LES FENETRES ET LES ISOLATIONS MOBILES A PARTIR D'ESSAIS SUR DES BOITES CHAUDES DANS DEUX LABORATOIRES COMMERCIAUX.

U VALUE MEASUREMENTS FOR WINDOWS AND MOVABLE INSULATIONS FROM HOT BOX TESTS IN TWO COMMERCIAL LABORATORIES.

Auteurs : MCCABE M. E.

Résumé

QUATRE COMPOSANTS REPRESENTATIFS DE FENETRES A GAINS DE CHALEUR DIRECTS, COMPRENANT UNE DOUBLE-FENETRE ET TROIS FENETRES SIMPLES AVEC ISOLATIONS MOBILES, ONT ETE ACHETES ET PREPARES EN VUE DES ESSAIS. ON A MESURE LES VALEURS DE K POUR CHAQUE ELEMENT D'ESSAI DANS DEUX LABORATOIRES D'ESSAI COMMERCIAUX UTILISANT LES METHODES ASTM C236 ET AAMA. LA COMPARAISON DES RESULTATS D'ESSAI AVEC LES COEFFICIENTS K DU CONSTRUCTEUR POUR LES ELEMENTS A FAIT APPARAITRE DES ECARTS DE 20 A 117 %. POUR LES ISOLATIONS MOBILES ESSAYEES, LES ECONOMIES D'ENERGIE VANTEES PAR LE CONSTRUCTEUR ONT ETE AUSSI SUREVALUEES. LES RESULTATS D'ESSAI SONT COMPARES D'UN LABORATOIRE A L'AUTRE ET L'ON NOTE DES DIFFERENCES LA OU DES VITESSES DU VENT DE 6,7 M/S ETAIENT SIMULEES. LES DIFFERENCES SONT ATTRIBUEES AUX DIFFERENTES DIRECTIONS UTILISEES POUR LA SIMULATION DU VENT.

Détails

  • Titre original : U VALUE MEASUREMENTS FOR WINDOWS AND MOVABLE INSULATIONS FROM HOT BOX TESTS IN TWO COMMERCIAL LABORATORIES.
  • Identifiant de la fiche : 1987-0671
  • Langues : Anglais
  • Date d'édition : 1986
  • Source : Source : ASHRAE Trans.
    vol. 92; n. 1A; 453-473; 12 fig.; 2 tabl.; 8 ref.; discuss.; append.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.