Mesures de rénovation pour réduire les besoins de refroidissement de bâtiments dans un environnement où les besoins de froid sont prépondérants: la maison individuelle.
Retrofitting measures for reducing buildings cooling requirements in cooling-dominated environment: residential house.
Auteurs : KHARSEH M., KHAWAJA M. al-
Type d'article : Article
Résumé
Air conditioning systems in hot and developing countries are the major energy consumers. Unfortunately, Arabian Peninsula countries still rely completely on fossil fuel. Therefore, there are compelling reasons to investigate the energy consumption in buildings and its environmental impact.
The current paper studies the effect of different retrofitting measures for reducing cooling load of buildings in hot climate. A common type of residential house with dimension of 12?×?12?×?3?m in Qatar was chosen as a case study. Five energy retrofitting measures of the building envelope have been considered in this study: (1) U-value of the external shell, (2) indoor set-temperature, (3) lighting efficacy, (4) the color of external shell, and (5) windows' quality. Hourly analysis program was used for calculating the cooling load of the case study. The anticipated costs associated with the implementation of the retrofitting measures were calculated based on the local current prices in Qatar. Simple payback period for each measure was assessed in the present study. The simulations show that the energy saving of 53% can be obtained at the working conditions of Qatar. The payback period of the examined measures is relatively short and varies between 0.5 and 4 years.
Détails
- Titre original : Retrofitting measures for reducing buildings cooling requirements in cooling-dominated environment: residential house.
- Identifiant de la fiche : 30017297
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
- Date d'édition : 05/04/2016
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.12.063
Liens
Voir d'autres articles du même numéro (61)
Voir la source
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Économie; Immeuble; Conversion; Conditionnement d'air; Charge frigorifique; Climat chaud
-
MOISTURE PROBLEMS IN BUILDINGS IN HOT HUMID CLI...
- Auteurs : LOTZ W. A.
- Date : 1989
- Langues : Anglais
- Source : ASHRAE Journal - vol. 31 - n. 4
Voir la fiche
-
AIR CONDITIONING IN HOT CLIMATES.
- Auteurs : DAVIDSON D.
- Date : 1982
- Langues : Anglais
Voir la fiche
-
Coefficient de charge frigorifique additionnell...
- Auteurs : LIN K., XU H.
- Date : 07/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 266
- Formats : PDF
Voir la fiche
-
Cooling load calculations for radiant systems: ...
- Auteurs : BAUMAN F., FENG J., SCHIAVON S.
- Date : 12/2013
- Langues : Anglais
- Source : ASHRAE Journal - vol. 55 - n. 12
Voir la fiche
-
Thermal comfort and building design in the trop...
- Auteurs : MALLICK F. H.
- Date : 1996
- Langues : Anglais
- Source : Energy Build. - vol. 23 - n. 3
Voir la fiche