Document IIF

Méthodes de mesurage de la composition en circulation de frigorigènes à base de mélanges binaires zéotropes.

Methods of measuring circulation composition for zeotropic binary mixture refrigerants.

Auteurs : HAIDER M., ELBEL S.

Type d'article : Article de la RIF

Résumé

Zeotropic blends allow for tailoring refrigerant properties to achieve desirable global warming potential (GWP) and flammability characteristics. However, composition shift between the circulation and the nominal composition in blends, necessitate accurate measurement of the circulation composition. This study reviews existing exsitu and in-situ methods for measuring circulation composition, and introduces a novel, cost-effective ex-situ measurement technique based on the pressure-temperature-density (PTD) gas method. This method measures binary mixture composition in the presence of oil, with an uncertainty of ±0.02 in mass fraction. It is more portable and affordable than traditional gas chromatography (GC), though with some tradeoffs in accuracy. In a chiller system using R134a and R32 blends, the PTD gas method detects a circulation composition shift of 0.03–0.06 from the nominal value. Additionally, three in-situ estimation techniques – pressure-temperaturequality (PTx), pressure-temperature-enthalpy (PTh), and pressure-temperature-density (PTD) liquid – are evaluated for measuring circulation composition without sample withdrawal. The PTx and PTh methods underestimate composition by 0.02–0.08, while the PTD liquid method overestimates by 0.08–0.12. These discrepancies cause the peak COP to shift relative to the ex-situ PTD gas measurement. The peak COP is 2–3 % lower using nominal composition, PTx and PTh methods, whereas the PTD liquid method overestimates it by nearly 3 %. Thus, calibration of in-situ methods is recommended to enhance accuracy of in-situ methods using an ex-situ technique. These findings may aid experimental analysis, blend system control and field diagnosis, potentially enabling precise topping-off of leaking systems without full refrigerant replacement.

Documents disponibles

Format PDF

Pages : 12 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Methods of measuring circulation composition for zeotropic binary mixture refrigerants.
  • Identifiant de la fiche : 30034404
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 177
  • Date d'édition : 09/2025
  • DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.05.022

Liens


Voir d'autres articles du même numéro (34)
Voir la source

Indexation

  • Thèmes : N/A
  • Mots-clés : N/A