Mini thermosiphon diphasique pour le refroidissement d’équipements électroniques : modélisation dynamique, validation expérimentale et application à des serveurs 2U.
Two-phase mini-thermosyphon electronics cooling: Dynamic modeling, experimental validation and application to 2U servers.
Auteurs : LAMAISON N., ONG C. L., MARCINICHEN J. B., et al.
Type d'article : Article
Résumé
Gravity-driven cooling systems employing microchannel flow boiling can become a scalable and viable long term solution for the cooling of datacenter servers. In order to design this emerging type of cooling system, a new dynamic simulation tool using interconnected PDEs is described in the first part of the present paper followed by the validation of the modeling for both steady and dynamic regimes using a first-of-a-kind 15 cm-height thermosyphon test bench. A corrected error of 0.4 K was found for 7 different steady-state mean chip temperatures and heat load disturbances were predicted with the same 2-stage process presented here as the experimental results. The code was then used to predict the behavior of a mini-thermosyphon that would fit within the height of a 2U server. Multiple steady-state solutions were found with both stable and unstable operating states. A sensitivity study demonstrated that a 30% increase in the riser internal diameter led to 10–60% increase in the mass flow rate depending on the heat flux. Then, simulations with unbalanced heat loads showed that the flow gets self-redistributed into the CPU with the highest heat load, e.g. 1.7 times larger flow rate for a heat flux 3 times larger. Finally, heat load and water coolant flow rate disturbances were also simulated and discussed.
Détails
- Titre original : Two-phase mini-thermosyphon electronics cooling: Dynamic modeling, experimental validation and application to 2U servers.
- Identifiant de la fiche : 30020521
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 110
- Date d'édition : 05/01/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.08.198
Liens
Voir d'autres articles du même numéro (49)
Voir la source
Indexation
-
An experimental investigation of an R744 two-ph...
- Auteurs : TONG Z., DING T., LI Z., et al.
- Date : 05/11/2015
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 90
Voir la fiche
-
Development of an integrated air conditioner wi...
- Auteurs : HAN L., SHI W., WANG B., et al.
- Date : 01/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
Voir la fiche
-
Expérience à échelle réelle pour un système de ...
- Auteurs : TSUCHIYA T., SUWA Y., OOKA R.
- Date : 11/2013
- Langues : Japonais
- Source : Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 200
Voir la fiche
-
Gaps in modeling data center energy.
- Auteurs : BEATY D. L., QUIRK D.
- Date : 11/2015
- Langues : Anglais
- Source : ASHRAE Journal - vol. 57 - n. 11
Voir la fiche
-
Into the cold.
- Auteurs : FLUCKER S., TOZER R.
- Date : 04/2012
- Langues : Anglais
- Source : CIBSE Journal - vol. 4 - n. 4
Voir la fiche