Modélisation d'un système frigorifique à éjecteur fonctionnant sous des conditions de dimensionnement et d'absence de dimensionnement avec les fluides actifs R-142b et R-600a.
Modelling of an ejector refrigerating system operating in dimensioning and off-dimensioning conditions with the working fluids R-142b and R-600a.
Auteurs : BOUMARAF L., LALLEMAND A.
Type d'article : Article
Résumé
This paper describes a whole simulation program which is useful to evaluate the performance and the characteristics of the operating cycle of an ejector refrigerating system with the working fluids R-142b and R-600a. The cycle is determined using the temperatures of the three thermal sources and local heat transfer coefficients for the boiler, the condenser and the evaporator. In addition, the simulation program includes a correlation of the ejector entrainment ratio established in different operating conditions at critical point from the conservation equations of the 1-D model available in the literature. Previously, all the components of the system were dimensioned for a refrigerating power of 10 kW, the hot source temperature is equal to 120 and 130°C, whereas those of the intermediate and the cold sources are fixed at 35 and 10°C, respectively (dimensioning conditions). Then, the system performance is investigated in dimensioning conditions and in off-dimensioning conditions using the simulation program. Particularly, the analysis of the results shows that at fixed cold source temperature, the intermediate temperature corresponding to the critical mode, the system COP decreases when the hot source temperature is higher than that of its dimensioning. Consequently, it is recommended to dimension the system components at the highest possible temperature in order to guarantee better performance in the case of an operating at lower temperature of the hot source. Also, it is noted that R-142b leads to better performance of the system in all cases. This can be due to the fact that R-142b is a heavier fluid than R600a. [Reprinted with permission from Elsevier. Copyright, 2008].
Détails
- Titre original : Modelling of an ejector refrigerating system operating in dimensioning and off-dimensioning conditions with the working fluids R-142b and R-600a.
- Identifiant de la fiche : 2009-0609
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 2-3
- Date d'édition : 02/2009
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
-
Model development and numerical procedure for d...
- Auteurs : OUZZANE M., AIDOUN Z.
- Date : 12/2003
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 23 - n. 18
Voir la fiche
-
The behaviour of a hybrid compressor and ejecto...
- Auteurs : HERNÁNDEZ J. I., DORANTES R. J., BEST R., et al.
- Date : 09/2004
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 24 - n. 13
Voir la fiche
-
Performances d'une machine de réfrigération à é...
- Auteurs : LALLEMAND A., DORANTES R., STAADER J.
- Date : 20/08/1995
- Langues : Français
- Source : For a Better Quality of Life. 19th International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Numerical assessment of ejector operation for r...
- Auteurs : BARTOSIEWICZ Y., AIDOUN Z., MERCADIER Y.
- Date : 04/2006
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 5-6
Voir la fiche
-
A year-round dynamic simulation of a solar-driv...
- Auteurs : PRIDASAWAS W., LUNDQVIST P.
- Date : 08/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 5
- Formats : PDF
Voir la fiche