Modélisation de la limite de givrage d’un échangeur d'énergie à membrane air-air à quasi-contre-courant pour une utilisation dans des climats froids.
A frosting limit model of air-to-air quasi-counter-flow membrane energy exchanger for use in cold climates.
Auteurs : LIU P., MATHISEN H. M., ALONSO M. J., et al.
Type d'article : Article
Résumé
Membrane energy exchangers (MEEs) can reduce or avoid frosting in cold climates since the moisture transfer lowers the dew point of the exhaust air and as a result, the exchanger can be frost-free at lower outdoor air temperatures or higher indoor humidities. A frosting limit is necessary to predict at which conditions the onset of frost occurs for a given membrane energy exchanger. The frosting limit model provides criteria for energy exchanger selection and frost control methods to avoid frosting.
A theoretical frosting limit model is developed in this study for a quasi-counter-flow MEE. The frosting limit model uses analytical relationship between the onset of frosting at the coldest location of the exchange and the inlet air conditions. The model is validated with experimental data and consistent agreements are obtained between the theoretical and experimental data. Parametric studies are conducted using the validated model. The influence of airflow rates, exhaust air temperature and channel spacing on the frosting limit is rather limited compared to the diffusive resistance of moisture transfer. A membrane with improved moisture transfer properties is crucial to implement frost-free operation at normal indoor relative humidities.
Détails
- Titre original : A frosting limit model of air-to-air quasi-counter-flow membrane energy exchanger for use in cold climates.
- Identifiant de la fiche : 30020933
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 111
- Date d'édition : 25/01/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.10.010
Liens
Voir d'autres articles du même numéro (32)
Voir la source
Indexation
-
An analytical model for predicting frosting lim...
- Auteurs : NAVID P., NIROOMAND S., SIMONSON C. J.
- Date : 03/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 99
- Formats : PDF
Voir la fiche
-
Membrane energy exchangers, evaluation of a fro...
- Auteurs : LIU P., ALONSO M. J., MATHISEN H. M.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Thermal performance of louvered fin-tube heat e...
- Auteurs : LIM J., PARK W., CHO K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Incorporating a frost growth model with segment...
- Auteurs : PADHMANABHAN S., FISHER D. E., CREMASCHI L.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Parametric evaluation of governing heat and mas...
- Auteurs : ARMATIS P. D., FRONK B. M.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche