Modélisation des performances d'un sèche-linge à pompe à chaleur thermoélectrique avec un débit d'air très élevé.
Performance modeling of a thermoelectric heat pump clothes dryer with very high air flow.
Numéro : 2459
Auteurs : BOUDREAUX P., PATEL V., HALL C., GLUESENKAMP K., KARMAN S., ELLIS D., GEHL A.
Résumé
Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 CFM (0.06 m3/s) and provided about 1300 W of thermoelectric heating capacity with an experimentally measured energy factor of 6.89 lbc/kWh and 84-minute dry time (compared with ENERGY STAR criteria of >3.93 lbc/kWh and <80 minutes). In this work, an experimentally validated thermohydraulic model is presented that was used to explore the performance of a very high air flow rate thermoelectric heat pump clothes dryer. Modeled performance shows that an energy factor > 7 lbc/kWh with a dry time < 80 minutes is achievable with an airflow rate of 240 CFM (0.11 m3/s) and 600 W of thermoelectric heating capacity.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Gratuit
Détails
- Titre original : Performance modeling of a thermoelectric heat pump clothes dryer with very high air flow.
- Identifiant de la fiche : 30030738
- Langues : Anglais
- Sujet : Technologie
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 2022
Liens
Voir d'autres communications du même compte rendu (224)
Voir le compte rendu de la conférence
-
Performance of a metal hydride cooling module.
- Auteurs : AJAY M., MAIYA M. P., SRINIVASA MURTHY S.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
System modeling of gas engine driven heat pump.
- Auteurs : MAHDEREKAL I., SHEN B., VINEYARD E. A.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Thermoelectric heat pump clothes dryer using se...
- Auteurs : PATEL V. K., GLUESENKAMP K. R.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental temperature fronts for adsorptive ...
- Auteurs : PONS M., LAURENT D., MEUNIER F.
- Date : 05/1996
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 16 - n. 5
Voir la fiche
-
Numerical analysis of adsorptive temperature wa...
- Auteurs : BEN-AMAR N., SUN L. M., MEUNIER F.
- Date : 05/1996
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 16 - n. 5
Voir la fiche