Modélisation et analyse de la pompe d'une tour de refroidissement : étude de cas.
Modelling and analysis of cooling tower pump: a case study.
Auteurs : ADHIKARY P., IQBAL F., SADRI R., et al.
Résumé
The purpose of this study is to identify, observe and determine the pattern of velocity, pressure, temperature profile etc. distribution by using CFD simulation program after the 3D design and modeling of the pump is made. The standard k-e turbulence model was chosen for turbulence model. From the simulation results it was observed that the pressure, velocity etc increases gradually from impeller inlet to outlet. The static pressure on pressure side is evidently larger than that on suction side at the same impeller radius. In addition to this, it was observed that, the velocity increases from impeller inlet until it enters the volute casing. It then drops to a minimum value at outlet region. Good agreement was found between the simulated results and obtained project data.
Documents disponibles
Format PDF
Pages : 4
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Modelling and analysis of cooling tower pump: a case study.
- Identifiant de la fiche : 30024774
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Date d'édition : 27/07/2018
Liens
Voir d'autres communications du même compte rendu (29)
Voir le compte rendu de la conférence
-
Cost-optimal analysis of cooling towers.
- Auteurs : KINTNER-MEYER M., EMERY A. F.
- Date : 1994
- Langues : Anglais
- Source : ASHRAE Transactions 1994.
Voir la fiche
-
A methodology for the evaluation of cooling tow...
- Auteurs : BECKER B. R., BURDICK L. F.
- Date : 1992
- Langues : Anglais
- Source : ASHRAE Transactions 1992. Part 2.
Voir la fiche
-
Laboratory observations of biocide efficacy in ...
- Auteurs : SMITH I., FRICKER E. J., ECCLES J.
- Date : 2004
- Langues : Anglais
- Source : ASHRAE Transactions. 2004 Annual Meeting, Nashville, Tennessee, USA. Volume 110, part 2 + CD-ROM.
Voir la fiche
-
NEAR-OPTIMAL CONTROL OF COOLING FOR CHILLED-WAT...
- Auteurs : BRAUN J. E., DIDERRICH G. T.
- Date : 1990
- Langues : Anglais
Voir la fiche
-
Alternative cooling tower water treatment methods.
- Auteurs : WILSEY C. A.
- Date : 16/02/1996
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche