Document IIF
Nouveau modèle de performance basé sur le taux d’utilisation de la capacité d’un système de conditionnement d’air à débit de frigorigène variable.
A novel performance model based on capacity utilization rate of variable refrigerant flow air conditioning system.
Résumé
In the background of huge market share (60 billion CNY in China in 2020), it is of great significance to improve the actual performance of the variable refrigerant flow (VRF) air conditioning system. Operation states of indoor units (IUs) have essential impact on energy efficiency of the VRF system with multiple indoor terminals. Thus, depicting the operation characteristics of IUs collectively and concisely to analyse its impact on system performance is a difficult problem to be solved. This paper investigated a novel performance affecting index of capacity utilization rate (CUR) to depict the impact of IUs on system performance, and established a performance model based on the index. Simulation results in cooling condition prove that both energy efficiency and evaporating temperature decrease with the decrease of CUR under a certain ambient temperature and part load rate. The research provides important guidance for system design, performance
simulation and performance evaluation for VRF system.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A novel performance model based on capacity utilization rate of variable refrigerant flow air conditioning system.
- Identifiant de la fiche : 30031747
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0246
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Model-free control and automatic staging of var...
- Auteurs : DONG L., LI Y., SALSBURY T. I., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Cooling capacity demand-induced cooperative con...
- Auteurs : CAO H., ZHUANG D., LEI J., DING G., HUANG Z., LI S., LI J., ZHANG H.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Performance evaluation of a combined variable r...
- Auteurs : AL-AIFAN B., PARAMESHWARAN R., MEHTA K., et al.
- Date : 04/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 76
- Formats : PDF
Voir la fiche
-
Comparaison et analyse appliquées à un système ...
- Auteurs : WANG L.
- Date : 04/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 276
- Formats : PDF
Voir la fiche
-
Étude expérimentale sur la charge optimale de f...
- Auteurs : WANG H., ZHANG S., YUAN H., et al.
- Date : 06/2015
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 36 - n. 163
Voir la fiche