Optimisation d’une pompe à chaleur géothermique résidentielle au moyen d’échangeurs thermiques à tubes de faible diamètre.
Optimization of a residential air source heat pump using heat exchangers with small diameter tubes.
Numéro : pap. 2066
Auteurs : BESHR M., AUTE V., RADERMACHER R.
Résumé
Heat exchangers play significant role in refrigeration and air conditioning systems. Ongoing research aims to improve, or at least maintain, the system performance while reducing the size, weight and cost of the heat exchangers. This in turn leads to lower system refrigerant charge and reduced environmental impact. Using heat exchangers with small tube diameters (less than 5 mm) instead of large tube diameters has been shown to be a promising solution to meet the aforementioned goals. However, shifting towards small tube diameters requires in-depth analysis and optimization of several heat exchanger design parameters. This paper presents a multi-objective optimization of a residential air source heat pump system using genetic algorithms with a particular focus on the use of small diameter tubes in the heat exchangers. The objectives are to minimize the heat exchangers’ cost and maximize the system performance. The goal of this study is to determine the potential material savings and cost reduction when using tube diameters between 3 mm and 5 mm in the heat exchangers. In addition to the tube diameters, multiple fin types, tube spacing and fin densities are also investigated. The optimization is carried out for R-410A, and a lower-GWP alternative, R-32. The system utilizing the improved heat exchanger designs has a cost reduction of 60% in comparison to the baseline system. Also, the improvements in the system’s COP and the system charge reduction are around 20% and 35%, respectively.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimization of a residential air source heat pump using heat exchangers with small diameter tubes.
- Identifiant de la fiche : 30018625
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
-
Multi-objective optimization of a residential a...
- Auteurs : BESHR M., AUTE V., RADERMACHER R.
- Date : 07/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Formats : PDF
Voir la fiche
-
Performance investigations of an R404A air-sour...
- Auteurs : JIN L., CAO F., YANG D., et al.
- Date : 07/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Formats : PDF
Voir la fiche
-
Experimental testing of solar photovoltaic/ther...
- Auteurs : BELTRAN F., SOMMERFELDT N., MADANI H.
- Date : 15/05/2023
- Langues : Anglais
- Source : 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Formats : PDF
Voir la fiche
-
Modelica based heat pump model for transient an...
- Auteurs : LING J., ALABDULKAREM A., QIAO H. T., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation of condenser with sm...
- Auteurs : WANG T., LIU Z., GAO N., FAN T., ZHAO H., GAO Y.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche