Optimisation de l'espacement des ailettes d'un échangeur de chaleur à tubes ailetés sous des conditions de givrage.

Fin spacing optimization of a fin-tube heat exchanger under frosting conditions.

Auteurs : YANG D. K., LEE K. S., SONG S.

Type d'article : Article

Résumé

Optimal values of the design parameters for a fin-tube heat exchanger of a household refrigerator under frosting conditions are proposed to improve its thermal performance and extend its operating time. In the optimization procedure, fin spacings of the heat exchanger are selected as the design parameters, and the average heat transfer rate, frost mass, and operating time are considered to be objectivefunctions. The response surface and Taguchi methods are employed to optimize the design parameters. As a result, the average heattransfer rate and operating time of the optimum models increases by up to 6.3 and 12.9% compared to that of the reference model,respectively. [Reprinted with permission from Elsevier. Copyright, 2006].

Détails

  • Titre original : Fin spacing optimization of a fin-tube heat exchanger under frosting conditions.
  • Identifiant de la fiche : 2006-2855
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 49 - n. 15-16
  • Date d'édition : 07/2006