Document IIF

Optimisation du coût d'un réfrigérateur magnétique à deux cylindres d'Halbach.

Concentric Halbach cylinder magnetic refrigerator cost optimization.

Auteurs : TURA A., ROWE A.

Type d'article : Article, Article de la RIF

Résumé

Commercial magnetic refrigeration near room temperature faces technological challenges and high costs. Although several laboratory devices have been developed, no design is realistically close to the performance, reliability, and financial proposition of a vapor compression refrigerator. This study examines the total cost of cooling provided by an idealized dual-regenerator concentric Halbach design. An optimization process, based on a simplified analytical model rather than a computationally intensive finite element model, is applied to geometrical and operational parameters, with the objective function minimizing capital and operating cost. Additionally, the model utilizes a refrigerant with ideal magnetocaloric (MCE) properties and constant specific heat. The model is first validated against extrapolated experimental data from an existing device, and then the optimization routine is applied to a range of cooling demand and MCE values. Results help in identifying target refrigerant properties, and refrigerator geometrical/operational parameters. Moreover, a sensitivity analysis demonstrates how the design variables affect the system performance.

Documents disponibles

Format PDF

Pages : 106-116

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Concentric Halbach cylinder magnetic refrigerator cost optimization.
  • Identifiant de la fiche : 30009887
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 37 - n. 1
  • Date d'édition : 01/2014

Liens


Voir d'autres articles du même numéro (37)
Voir la source