Optimisation expérimentale de la performance thermique d'un refroidisseur de fluide sec et adiabatique.
Experimental optimization of the thermal performance of a dry and adiabatic fluid cooler.
Auteurs : LUCAS M., MARTINEZ P., CUTILLAS C. G., et al.
Type d'article : Article
Résumé
The energy and environmental implications of a refrigeration cycle are largely conditioned by the choice of the condensing system. The dry and adiabatic fluid cooler works as a standard fluid dry cooler enhancing its capacity with adiabatic pre-cooling of the air intake. The objective of this study was to experimentally optimize the thermal performance of a dry and adiabatic fluid cooler. The experimental study has shown how the efficiency of the evaporative section decreases when air flow velocity increases. With respect to the product of the global heat transfer coefficient and the area (UA), we have seen how it increases by increasing the air velocity through the outside of the pipes and when the water flow inside increases. A model has been set to search for the optimal operating velocity. The average and maximum differences between the modeling and experimental outlet water temperatures are 0.30°C and 0.92°C respectively. The effect of ambient temperature and relative humidity on the outlet water temperature is also shown. For an ambient temperature of 30°C and 50% relative humidity, the outlet water temperature of the dry and adiabatic fluid cooler is 7.5°C lower than a dry system.
Détails
- Titre original : Experimental optimization of the thermal performance of a dry and adiabatic fluid cooler.
- Identifiant de la fiche : 30011412
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 69 - n. 1-2
- Date d'édition : 08/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2014.04.033
Liens
Voir d'autres articles du même numéro (7)
Voir la source
-
Mathematical modeling of a low temperature low ...
- Auteurs : NASRABADI M., FINN D. P.
- Date : 03/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 64 - n. 1-2
Voir la fiche
-
Waardoor wordt de werking van een dauwpuntkoele...
- Auteurs : JANSSEN M., UGES P. G. H.
- Date : 12/2010
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 103
Voir la fiche
-
Heat bus for the tropics: exergy analysis of co...
- Auteurs : BRUELISAUER M., MEGGERS F., ENGLER R., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Comparative study on the cooling performance of...
- Auteurs : YAN M., HE S., GAO M., XU M., MIAO J., HUANG X., HOOMAN K.
- Date : 01/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 121
- Formats : PDF
Voir la fiche
-
Theoretical analysis and experimental design of...
- Auteurs : GU Y., ZOU Y., PAN S., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche