Paramètres normalisés de performance pour une pompe à chaleur résidentielle en mode refroidissement avec défaillances uniques imposées.

Normalized performance parameters for a residential heat pump in the cooling mode with single faults imposed.

Auteurs : CHO J. M., HEO J., PAYNE W. V., et al.

Type d'article : Article

Résumé

The cooling mode performance of a residential split heat pump operating under nine different faults was described using normalized performance parameters determined from a ratio of the fault value to the no-fault value obtained from heat pump tests in environmental chambers. The normalized parameters were the coefficient of performance (COP), total capacity, refrigerant-side capacity, sensible heat ratio, outdoor unit power, and total power. A correlation for the normalized performance parameters was developed to produce a continuous representation of the performance characteristics given the fault level and indoor and outdoor temperature conditions.

Détails

  • Titre original : Normalized performance parameters for a residential heat pump in the cooling mode with single faults imposed.
  • Identifiant de la fiche : 30011463
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 67 - n. 1-2
  • Date d'édition : 06/2014
  • DOI : http://dx.doi.org/10.1016/j.applthermaleng.2014.03.010