Résumé
The installation cost and coefficient of performance (COP) of a ground source heat pump (GSHP) system can be greatly affected by the design of its ground loop. An experimental investigation was conducted to compare the performance of two loop designs for use with the ground source heat pump of an ‘energy pile’ installation or a conventional borehole system. A coaxial loop (a 40 mm OD coaxial tube with a 20 mm OD interior pipe) and a U-tube (20 mm OD pipes) of a length of 72 m were constructed, tested and analysed in terms of ground heat extraction capability and hydraulic flow characteristics. The use of the coaxial loop design could potentially reduce the cost of drilling boreholes and make the installation easier on site, as the effective diameter would be smaller than a comparable U-tube with the same mass flow rate, considering that the U-tube requires a minimum 10 mm spacer between the legs. Hydraulic performance tests have shown that the U-tube achieved the transitional-turbulent flow at a glycol flow rate of approximately 0.14L/s, whereas the flow in the coaxial remained laminar across the glycol flow rate range of 0.05e0.25L/s. Heat pump performance tests have shown that the U-tube achieved a COP of at least 0.08 greater than the coaxial loop across the range of glycol flow rates investigated, while the heat output was at least 12% greater when using the U-tube. Therefore, it can be concluded that the coaxial loop in its current form is seen not to add any performance benefit against the U-tube. [Reprinted with permission of Elsevier. Copyright 2012.]
Détails
- Titre original : Comparative performance of ‘U-tube’ and ‘coaxial’ loop designs for use with a ground source heat pump.
- Identifiant de la fiche : 30003700
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 37
- Date d'édition : 05/2012
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2011.11.015
Liens
Voir d'autres articles du même numéro (9)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Efficacité energétique, économie d'énergie - Mots-clés : Boucle; Conception; Sol; Pompe à chaleur; Experimentation; COP
-
Impact of the ground-source heat pump running t...
- Auteurs : SOLDO V., RUSEVLJAN M., GROZDEK M., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Improvements of U-pipe borehole heat exchangers...
- Auteurs : ACUÑA J.
- Date : 2010
- Langues : Anglais
Voir la fiche
-
Détermination de la profondeur pour des échange...
- Auteurs : YU Z., HU P., XU Y., et al.
- Date : 03/2009
- Langues : Chinois
- Source : HV & AC - vol. 39 - n. 222
- Formats : PDF
Voir la fiche
-
Estudio teórico de selección de componentes par...
- Auteurs : MONTAGUD C., CORBERÁN J. M.
- Date : 22/02/2012
- Langues : Espagnol
- Source : CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
Voir la fiche
-
Influence of system design on the efficiency of...
- Auteurs : FAHLÉN P.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche