Document IIF
Performance d'inflammabilité et évaluation expérimentale d'un nouveau mélange comme alternative à faible PRP au R404A.
Flammable performance and experimental evaluation of a new blend as R404A lower-GWP alternative.
Résumé
Current alternatives to R404A are either refrigerants with higher global warming potentials (GWP) from 1200 to 2000 or mildly flammable refrigerants with a charge limit of 1.2 kg. Therefore, nonflammable alternatives to R404A with lower GWP values need to be developed. In this study, a new non-flammable refrigerant blend, named RTJU-Z (GWP of 794), has been proposed to directly replace R404A in a cold storage system with no modification. The flammability and thermodynamic performance of RTJU-Z were studied experimentally. The results show that RTJU-Z couldn't be ignited successfully and had a higher coefficient of performance (COP) value than that of R404A by 2.15%-5.71% at different cold storage temperatures. The optimal charge of RTJU-Z for the experimental system was 11.76% lower than that of R404A. The refrigeration capacity of RTJU-Z was about the same as that of R404A at the cold storage temperature from -20 °C to 10 °C. It is concluded that RTJU-Z can be directly used as a non-flammable alternative to R404A in a cold storage system with no modification.
Documents disponibles
Format PDF
Pages : 113-120
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Flammable performance and experimental evaluation of a new blend as R404A lower-GWP alternative.
- Identifiant de la fiche : 30029368
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 135
- Date d'édition : 03/2022
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.12.019
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (26)
Voir la source
Indexation
-
Thèmes :
Mélanges;
HFC;
Mesures thermodynamiques - Mots-clés : R404A; Inflammabilité; Propriété thermodynamique; GWP; Entreposage frigorifique; Mélange; HFC; Experimentation
-
Thermodynamic and flammable performance of a ne...
- Auteurs : ZHANG L., YANG Z., LV Z., ZHAI R., DENG Q
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche
-
The developing of lower GWP refrigerants.
- Auteurs : OHKUBO S., FLOHR F., GOBOH K., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Flammability limits of theoretical azeotropic m...
- Auteurs : WU X., OU Z., GUAN H., ZHU X., YANG Z., XU S.
- Date : 03/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 159
- Formats : PDF
Voir la fiche
-
Reduced GWP refrigerants for residential and co...
- Auteurs : ZOU Y., SETHI A., YANA MOTTA S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Reduced GWP refrigerants for residential and co...
- Auteurs : ZOU Y., SETHI A., YANA MOTTA S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche