Performance des frigorigènes alternatifs R410A et R22 à des températures ambiantes élevées.
Performance of R410A and R22 low GWP alternative refrigerants at elevated ambient temperatures.
Numéro : pap. 2381
Auteurs : SCHULTZ K.
Résumé
Growing concerns about the global warming impact of refrigerants used in HVAC&R equipment are driving development and evaluation of alternative refrigerants with lower global warming potentials (GWPs). The Air Conditioning, Heating, and Refrigeration Institute (AHRI) recently coordinated the Low-GWP Alternative Refrigerant Evaluation Program (AREP) in which commercial, university, and government laboratories ran tests of a range of alternative refrigerants in a variety of HVAC&R products. This paper reports the performance of a 4.4 RT (15.5 kW) air-cooled water chiller / heat pump run with a number of lower GWP alternative refrigerants. Tests were first run with a compressor designed for R410A-like pressures. The refrigerants tested include R410A (baseline) and R32, along with blends labeled DR-5, DR-4, L-41a, L-41b, ARM- 70a, ARM-32a, and HPR1D. The compressor was then replaced with one designed for R22-like pressures. The refrigerants tested include R22 (baseline) along with blends labeled DR-4, DR-7, ARM-32a, L-20, LTR4X, and LTR6A. The blends contain R32, R1234yf, R1234ze(E), R134a, R152a, R125, and R744 (CO2). The results of this project have been reported previously for performance measured at the nominal operating condition of 7.2°C (45°F) leaving chiller water temperature and 35°C (95°F) ambient air temperature (Schultz and Kujak, 2012, 2013a, 2013b; Schultz, 2014). In this paper, performance over an extended range of air temperatures from 24°C to 46°C (75°F to 115°F) is reported and compared to a simple thermodynamic cycle model. The predicted performance benefits of some refrigerants were not observed at elevated air temperatures in the equipment tested. However, none of the alternative refrigerants performed significantly worse than R410A at elevated ambient air temperatures.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance of R410A and R22 low GWP alternative refrigerants at elevated ambient temperatures.
- Identifiant de la fiche : 30012988
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
-
Conditionneur d'air individuel.
- Auteurs : NAKAYAMA M., SUMIDA Y., TANIMURA Y.
- Date : 05/1997
- Langues : Japonais
- Source : Refrigeration - vol. 72 - n. 835
Voir la fiche
-
Recherche expérimentale sur la performance d’un...
- Auteurs : LIU Z., HU M., LI T.
- Date : 04/2018
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 39 - n. 2
- Formats : PDF
Voir la fiche
-
Performance of an R-410A room air conditioner m...
- Auteurs : JANICKI C., HERMANN K., NEUMAN J., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Evaluation and soft-optimization for R410A low-...
- Auteurs : ALABDULKAREM A., ELDEEB R., HWANG Y., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Retrofit assessment of window air conditioner.
- Auteurs : TENG T. P., MO H. E., LIN H., et al.
- Date : 01/2012
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 32
Voir la fiche